Glossary

Help make your window or door buying
experience a more informed one by familiarizing yourself with some
of these words and phrases which may come up in your conversations with
us.
Apron: Inside flat trim member which is used
under the stool at the bottom of the window.
Astragal: The center member of a double door, which is attached to the fixed
or inactive door panel.
Bay window: A composite of three or more windows, usually made up of a large
center unit and two flanking units at 30°, 45° or 90° angles to the wall.
Bow window: A composite of four or more window units in a radial or bow formation
Brick mould: Outside casing around window to cover jambs and through which nails
are driven to install the window.
Casing: Inside casing is a flat, decorative moulding that covers the inside edge
of the jambs and the rough openings between the window unit and the wall. Outside
casing (or brick mould, above) serves the same purpose, while it also is an installation
device through which nails are driven to install the window unit into the wall.
Check rail: On a double-hung window, the bottom rail of the upper sash and the
upper rail of the lower sash, where the lock is mounted.
Circlehead: A generic term referring to any of a variety of window units with
one or more curved frame members, often used over another window or door opening.
Clerestory: A window near the top of an outside wall.
Cottage double-hung: A double-hung window in which the upper sash is shorter
than the lower sash.
Cripples: The short 2" x 4" members used to frame under the sill or
above the header in a rough opening for a window in a frame wall.
Curb: A watertight wall or frame used to raise slope glazing above the surface
of the roof as a preventive measure against water leakage from melting snow or
rain run-off.
Design Pressure: A numerical value that defines the structural wind loading requirements
(in pounds per square foot) for a building and the components and cladding of
a building.
Dormer: A space which protrudes from the roof, usually including one or more
windows.
Double glazing: Use of two panes of glass in a window to increase
energy efficiency and provide other performance benefits.
Double hung: A window with two vertical operating sash that slide up and down.
Double rafter: The doubling (side by side) of the roof members to reinforce an
opening in the roof for a slope-glazing installation.
Drip cap: A moulding placed on the top of the head brick mould or casing of a
window frame.
Egress window: A window large enough, as defined by local building
codes, for exit or entry in case of an emergency. Typically required in bedrooms.
Fenestration: An architectural term referring to the arrangement of windows in
a wall.
Finger-jointing: A means of joining individual pieces of wood together to form
longer lengths. The ends of the pieces are machined to form a set of interlocking
fingers, which are then coated with adhesive and meshed together under pressure.
Fixed: Non-venting or non-operable.
Flashing: A metal or plastic strip attached to the outside of the head or side
jambs to provide a weather barrier, preventing leakage between the frame and
the wall.
French hinged door: Hinged door(s) which have wider panel members around the
glass.
French sliding door: A sliding door which has wider panel members around the
glass, giving the appearance of a French hinged door.
Gasket: A pliable, flexible continuous strip of material used to effect a watertight
seal between sash and frame of roof windows much like the seal around a refrigerator
door.
Glazing: The glass panes or lights in the sash of a window. Also the act of installing
lights of glass in a window sash.
Glazing bead: A plastic or wood strip applied to the window sash around the perimeter
of the glass.
Glazing compound: A pliable substance applied between the window sash and the
lights of glass to seal against the elements and sometimes to adhere the glass
to the sash.
Glazing stop: The part of the sash or door panel which holds the glass in place.
Head: The main horizontal member forming the top of the window or door frame.
Head board: A flat board cut to fit the contour of a bow or bay window and installed
between the head jambs and the flat wall surface to finish off that area which
would normally be ceiling.
Header: A heavy beam extended across the top of the rough opening to prevent
the weight of wall or roof from resting on the window frame.
Hopper: A window with a top sash that swings inward.
Impact Resistant Glass: Single or double pane construction made up of laminated
glass containing a .090 interlayer.
Jack stud: Framing members, generally 2" x 4"s, which form the inside
of the window or door rough opening. They run from the sole plate to the header,
which is supported by them.
Jamb liner: Metal or plastic covering the inside surface and head jambs of sliding
windows.
Keeper: The protruding, hook-shaped part of a casement window lock, which is
mounted on the inside surface of the sash stile.
Lift: handle or grip installed on the bottom rail of the lower sash of a double-hung
window to make it easier to raise or lower the sash.
Light: (also spelled lite) Glazing framed by muntins and/or sash in a window
or door
Light shaft: An insulated shaft built to direct the light from a roof window
or skylight through the attic to the room below.
Low-E glass: A common term used to refer to glass which has low emissivity due
to a film or metallic coating on the glass or suspended between the two lights
of glass to restrict the passage of radiant heat.
Masonry openings: The opening in a masonry wall to accept a window or door unit,
the same as a rough opening in a frame wall.
Molding: An ornamental exterior trim around the perimeter of a frame.
Mortise: A slot or rectangular cavity cut into a piece of wood to receive another
part.
Mortise-and-tenon: A strong wood joint made by fitting together a mortise in
one board and a matching projecting member (tenon) in the other.
Mullion: The vertical or horizontal divisions or joints between
single windows in a multiple window unit.
Mullion casing: An interior or exterior casing member to cover the mullion joint
between single windows.
Muntin: A short bar used to separate glass in a sash into multiple lights. Also
called a windowpane divider or a grille.
NFRC: National Fenestration Rating Council® -a non-profit organization that provides
fair, accurate and credible energy performance ratings for windows and doors.
Operator: A metal arm and gear which allows for easy operation or closing of
projecting windows.
Outer frame member: The exterior protruding portion of a window frame which has
no exterior casing.
Palladian window: A large, arch-top window flanked by smaller windows on each
side.
Panel: Usually refers to the separate panel or panels in a door frame.
Passive solar collector: Any glazed area in the walls or roof of a building pointed
to the south to take maximum advantage of the sun's heat without a mechanical
(or active) method of storage or distribution of the heat.
Picture frame casing: The use of casing on all four sides of the interior of
a window, replacing the stool and apron at the sill. Also known as full-bound
casing.
Pitch: The pitch of a roof is the degree of the inclination upward from horizontal
or flat. It may be expressed in degrees or as the ratio of the number of inches
it rises in each 12 inches of horizontal span: 4/12 means the roof rises four
inches in every foot of horizontal span.
Pivot: A mode of operation for ventilating windows which generally means the
sash pivots on a central axis and turns 90 or more degrees.
Rafter: Structural members of a roof that support the roof load and run from
the ridge to the eaves (overhang).
Rails: The horizontal members of a window sash or door panel.
Rough opening: The opening left in a frame wall to receive a window or door unit.
Rough sill: The horizontal rough framing member, usually two inches by four inches,
which forms the bottom of the rough opening. It is toe-nailed into the jack studs
and is supported by cripples.
Sash balance: A system of weights, cords and/or coiled springs which assist
in raising double-hung sash and tend to keep the sash in any placed position
by counterbalancing the weight of the sash.
Sash cord: In double-hung windows, the rope or chain that attaches the sash to
the counter balance.
Sash lock: Generally, a cam-action type lock applied to the check rails of a
sliding window or at the open edges of a projecting window to pull the check
rails tightly together or to seal the sash tightly to the frame, both for security
and weathertightness.
Sash weights: In older double-hung windows, the concealed cast-iron weights that
are used to counterbalance the sash.
Seat board: A flat board cut to fit the contour of a bow or bay window and installed
between the sills and the flat wall surface, providing a seat or shelf space.
Shims: A thin, waterproof piece of material used between the window/door unit
and the rough opening to support the unit, center it within the rough opening,
and adjust it to a plumb, level and square position. If tapered shims are used,
they must be used in pairs with the tapers opposing each other to avoid tilting
the unit or twisting the jambs.
Side lights: Tall, narrow, fixed or operating sash on either or both sides of
a door to light an entryway or vestibule.
Sill: Horizontal member that forms the bottom of a window frame.
Sill course (soldier course): The row of brick, cement blocks or stones laid
across the bottom of a masonry opening which lay under the outside edge of the
window sill.
Simulated divided light: A method of constructing windows in which muntins are
affixed to the inside and outside of a panel of insulating glass to simulate
the look of true divided light.
Single glazing: Use of single panes of glass in a window. Not as energy-efficient
as double glazing.
Single-hung: A double-hung type of window in which the top sash is fixed or inoperable.
Slope glazing: Any glazed opening in a sloped roof or wall, such as a stationary
skylight or fully operable roof window.
Solar gain: The process of providing a net heat gain within a structure, over
and above the normal heat loss, by passive collection of the sun's heat through
windows and other glazed areas.
Sole plate: The bottom horizontal member in a frame wall. Usually either single
or double 2" x 4"s. It is nailed to the deck or rough floor and the
studs are nailed into it.
Stile: The vertical side member of a window sash or door panel.
Stool: Inside horizontal trim member of a window sash or door panel.
Stop: A wood trim member nailed to the window frame to hold, position or separate
window parts. The stop is often moulded into the jamb liners on sliding windows.
Stud: Vertical wood framing members which form a frame wall. In normal construction
these are eight foot-long 2" x 4"s.
Tenon: A rectangular projection cut out of a piece of wood for insertion into
a mortise.
Transom: A smaller window above a door or another window. A transom joint is
also the horizontal joining area between two window units which are stacked one
on top of the other.
Triple glazing: A sash glazed with three lights of glass, enclosing two separate
air spaces.
True divided light: A term that refers to windows in which multiple individual
panes of glass or lights are assembled in the sash using muntins.
U-Factor: A measure of heat transmission through a wall or window. The lower
the U-Factor, the better the insulating value.
Unison lock: A casement locking system which secures the window at two locking
points by operation of one handle.
Vapor barrier: A watertight material used to prevent the passage of moisture
into or through floors, walls and ceilings.
Venting unit: A window or door unit that opens or operates.
Wind Bourne Debris Region: Areas within hurricane-prone regions within one mile
of the coast where the basic wind speed is 110mph or greater, or where the basic
wind speed is equal to or greater than 120mph, or Hawaii.
Windload: Force exerted on a surface by moving air.
Windowpane divider: A short bar used to separate glass in a sash into multiple
lights. Also called a muntin or a grille.
|